Безплатна доставка със Еконт над 129 лв
Speedy office 11.00 лв Speedy 13.00 лв ЕКОНТ 6.00 лв Еконтомат/Офис на Еконт 6.00 лв Box Now 6.00 лв

Balancing Exhaust Ventilation Systems

Език Английски езикАнглийски език
Книга С меки корици
Книга Balancing Exhaust Ventilation Systems Vivek Balasubramanian
Код Либристо: 06820851
Издателство VDM Verlag Dr. Müller, ноември 2008
Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §c... Цялото описание
? points 132 b
103.08 лв
Налично при издателя, по поръчка Изпращаме след 3-5 дни

30 дни за връщане на стоката


Може би ще Ви заинтересува


Airbus A320 pilot handbook: Simulator and checkride techniques Mike Ray / С меки корици
common.buy 62.83 лв
Hot Vegan Robin Robertson / С меки корици
common.buy 31.46 лв
Thirteen Albatrosses DONALD HARINGTON / С меки корици
common.buy 33.48 лв
In absentia [Judici a la Terra] Jordi Ortiz / С меки корици
common.buy 25.31 лв
Industrial Power Systems Sheeba Khan / С твърди корици
common.buy 580.21 лв
Sound Pulses F. G. Friedlander / С меки корици
common.buy 95.92 лв
Absurdist Angles on History Merritt Abrash / С меки корици
common.buy 38.12 лв
Affine Ebenen Artur Bergmann / С меки корици
common.buy 265.29 лв

Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically, the airflow through §each branch duct is estimated from the centerline §velocity pressure. To test the effectiveness of that §approach, dampers were adjusted on a seven branch, §full-sized experimental duct system. After adjusting §the dampers for a given condition, the percent §excess airflow (%Qexcess) for the system was §estimated as the amount above the ideal fan airflow §that would exist if the fan speed were adjusted so §that the lowest ratio of airflow to airflow goal for §any branch was unity. The lower the value of percent §excess airflow, the more perfectly balanced the §system was. The results varied with the level of the §target airflows. The excess airflow values were much §higher than the airflow values found by Dodrill §(2004) on the same system for the SPh Goal Ratio §method proposed by Guffey (2005). This analysis §should be useful to professionals in the fields of §HVAC and ventilation design.

Информация за книгата

Пълно заглавие Balancing Exhaust Ventilation Systems
Език Английски език
Корици Книга - С меки корици
Дата на издаване 2009
Брой страници 72
Баркод 9783639120301
Код Либристо 06820851
Издателство VDM Verlag Dr. Müller
Тегло 124
Размери 150 x 220 x 4
Подарете тази книга днес
Лесно е
1 Добавете книгата в количката си и изберете Доставка като подарък 2 В замяна ще ви изпратим ваучер 3 Книгата ще пристигне на адреса на получателя

Вход

Влезте в акаунта си. Още нямате акаунт за Libristo? Създайте го сега!

 
задължително
задължително

Нямате акаунт? Използвайте предимствата на акаунта за Libristo!

Благодарение на акаунта за Libristo държите всичко под контрол.

Създаване на акаунт за Libristo